Maintenance software for battery storage

Drop in your container layout and BMS alarm export: the register comes back in containers, racks and modules, with every system the container depends on.

Free for one site and up to 3 people. Team: £29 a month for each person who plans, £9 for each who does the work. Everyone who only reports or views is free.

Team opens in Q1 2027. Start free today and move up then.

What comes loaded

  • 27 kinds of equipment
  • 26 planned maintenance tasks
  • 9 checks for the phone
  • 6 duties tracked, each marked to be checked

Each battery site is laid out as compound or yard, container or enclosure bay, rack row, inverter station, substation, control building, fire water and emergency access.

  • Battery container
  • Battery rack
  • Battery module
  • Rack DC switchgear and fuses
  • Battery management system
  • Battery thermal management
  • Battery fire detection and suppression
  • Off-gas and gas detection
  • Deflagration venting and explosion ventilation
  • E-stop and door interlocks
  • Power conversion system
  • Transformer
  • Switchgear
  • Protection and control panel
  • Substation DC battery and charger
  • Earthing system
  • HV cable circuit
  • Energy management system
  • Power plant controller
  • SCADA RTU or gateway
  • UPS
  • Fire water tank and hydrants
  • CCTV
  • Access control
  • Perimeter fence
  • Gate or barrier
  • Spares container

Planned maintenance from day one

The first 10 of 26 starting plans
Task How often Who Where it comes from
Battery: annual capacity test against the warranty Every year Specialist Our library: check
Container: six-monthly inspection and DC thermography Every 6 months Your team Maker’s recommendation: check
Racks: annual torque check on a sample of DC connections Every year Specialist Maker’s recommendation: check
BMS: quarterly review Every 3 months Your team Maker’s recommendation: check
BMS: annual balancing and sensor check Every year Specialist Maker’s recommendation: check
Container cooling: quarterly service Every 3 months Specialist Maker’s recommendation: check
Container fire detection: six-monthly test and panel service Every 6 months Specialist Our library: check
Suppression: six-monthly service Every 6 months Specialist Maker’s recommendation: check
Gas detection: six-monthly bump test and calibration Every 6 months Specialist Maker’s recommendation: check
Deflagration panels and ventilation: annual inspection Every year Specialist Maker’s recommendation: check

Every interval is a starting point. The maker’s manual, the warranty and your own safety rules win, and you change any of them.

Checks on the phone

The forms come loaded. Filling them in on the phone: coming in Q1 2027.

  • Container entry checklist
  • Fire system check
  • Capacity test record
  • Thermal event or alarm investigation
  • Module replacement and return
  • Quarterly cooling service
  • Substation monthly inspection
  • Transformer inspection
  • Site security patrol

Duties we track in Great Britain so far

The duty rows come loaded. The register of duties with their dates: coming in Q1 2027.

6 duty rows in the pack
Duty Where What it rests on Status
Battery storage fire safety: detection, gas detection, suppression and venting UK Guidance: Grid scale battery energy storage system planning: guidance for fire and rescue services; The site's planning permission Check
Emergency response plan agreed with the fire and rescue service UK Guidance: Grid scale battery energy storage system planning: guidance for fire and rescue services Check
Risk assessment where flammable gas can build up Great Britain Law: Dangerous Substances and Explosive Atmospheres Regulations 2002, regulation 5 Check
Waste batteries taken out on replacement UK Law: Waste Batteries and Accumulators Regulations 2009 Check
F-gas leak check of battery cooling units Great Britain Law: Fluorinated Greenhouse Gases Regulations 2015; Regulation (EU) No 517/2014 as it applies in Great Britain, article 4 Check
Capacity test against the battery warranty UK Your contract or consent: The battery supply agreement and performance warranty Check

The legal duties are drafted from the public text each row cites and marked to be checked until a qualified person has reviewed them, in the product as here. Check your own duty-holder advice. Sites in other countries get the same plans and checks; their duty rows are added country by country.

In your words

container, rack, module, cell, BMS, PCS, EMS, SoC, SoH, augmentation, throughput, RTE, thermal runaway, off-gas.

What you watch: availability (by the contract’s formula); planned maintenance done on time; round-trip efficiency (by the contract’s formula); state of health trend; capacity test result against the warranty curve; cell temperature spread; alarms per container; fire system faults open.

What is not here yet

  • Permits to work, including HV and DC isolation: coming in Q2 2027.
  • Planned outages and shutdowns: coming in Q4 2027.

Common questions

Do contractors and clients pay?

No. Contractors, clients, requesters and viewers are free, with no limit. You pay for your own staff.

Do we have to keep the starting plans?

No. Every interval and check is a starting point: change it, switch it off or add your own.

Is this legal advice?

No. The duty rows say what the law or guidance they cite asks, and every one is marked to be checked. Check your own duty-holder advice.

More for energy: all energy pages.

Also: Solar farms.

Also: Wind farms.

See it on your own battery sites.

Free for one site, up to 3 people and 2,000 assets. No card.